The standardization of construction site standardization has become an essential requirement for civilized and safe construction sites. The Ministry of Housing and Urban Rural Development has made clear requirements for the regulations of edge protection railings on construction sites. Huasu Xinghong Industry will elaborate on the standards and requirements of edge protection railings on construction sites.
工地臨邊防護(hù)欄桿的標(biāo)準(zhǔn)和要求
Standards and requirements for edge protection railings on construction sites
1.高處作業(yè)面邊沿?zé)o圍護(hù)或圍護(hù)設(shè)施高低低于800mm時(shí),應(yīng)按照規(guī)定設(shè)置連續(xù)的臨邊防護(hù)設(shè)施。
When there is no enclosure along the edge of the high-altitude work surface or the height of the enclosure facilities is less than 800mm, continuous edge protection facilities should be set up according to regulations.
2.采用防護(hù)欄桿時(shí),上桿距離地面高度為1.0—1.2m,下桿距離地面高度為0.5-0.6m,橫桿長度大于2m,應(yīng)加設(shè)欄桿立柱,防護(hù)欄桿應(yīng)能承受任何方向的1KN的外力。
When using protective railings, the height of the upper pole from the ground is 1.0-1.2m, the height of the lower pole from the ground is 0.5-0.6m, and the length of the horizontal pole is greater than 2m. Railing columns should be added, and the protective railing should be able to withstand an external force of 1KN in any direction.
3.防護(hù)欄桿立面可采用網(wǎng)板或密目式網(wǎng)封閉,欄桿底端設(shè)置高度不低于180mm的擋腳板,
3. The facade of the protective railing can be enclosed with mesh panels or dense mesh safety nets, and a toe board with a height of no less than 180mm should be set at the bottom of the railing,
4.臨邊防護(hù)應(yīng)采用定型化、工具式的防護(hù)設(shè)施。
4. Edge protection should adopt standardized and tool style protective facilities.
臨邊防護(hù)欄桿的規(guī)定和制作要求:
Regulations and production requirements for edge protective railings:
1.立柱采用40×40方管,防護(hù)欄外框采用30×30mm方管,中間采用鋼板網(wǎng),鋼絲直徑或截面不小于2mm,底座采用Ф12×4個(gè)膨脹螺栓與地面牢固固定。
1. The column adopts 40 × 40 square tubes, the outer frame of the protective fence adopts 30 × 30mm square tube, with steel plate mesh in the middle, steel wire diameter or cross-section not less than 2mm, and base made of Ф twelve × Four expansion bolts are firmly fixed to the ground.
2.防護(hù)欄桿立桿高度1200mm,每檔標(biāo)準(zhǔn)長度為2000mm,底部設(shè)200mm高紅白或黑黃相間擋腳板。
2. The height of the protective railing pole is 1200mm, with a standard length of 2000mm for each level. A 200mm high red white or black yellow alternating foot board is installed at the bottom.
產(chǎn)品樣式:
Product style:
臨邊防護(hù)欄桿一般應(yīng)用的場所:
Places where edge protective railings are generally used:
(1)溝、坑,槽和深基礎(chǔ)周邊
(1) Gullies, pits, grooves, and deep foundation perimeter
(2)樓層周邊
(2) Surrounding floors
(3)樓梯側(cè)邊
(3) Staircase side
(4)平臺(tái)或陽臺(tái)邊
(4) Platform or balcony edge
(5)屋面周邊。
(5) Surrounding the roof.